step by step Instruction. 1. Know old password. To modify device password, enter MAIN MENU-> ACCOUNT. Here take admin as an example. (1) Click in the row of “admin”. (2) Tick in “Modify Password”, for default the box is gray; for other user the box is highlighted. (3) Enter old password and desired new password.
The X82B Series HDCVI DVR offers 4K recording on each HDCVI channel and a host of advanced features and functions. The X82B takes advantage of HDCVI technology for easy integration into existing video security systems while leveraging existing networks, cabling, and cameras. Penta-brid access technology seamlessly records video from HDCVI, AHD, TVI, CVBS, and IP sources simultaneously, plus

Step 3. Click on the Face Recognition option in the Parameters menu and verify the correct channel (camera number) is being used. As we mentioned, the camera must support AI features. Click on the Enable toggle switch to enable the face recognition feature. Click on Apply to save the settings.

(1) Enter Main Menu > SYSTEM > UPGRADE. (2) Insert the USB device that have the update file to the device. Click System Upgrade. (3) Click the file that you want to upgrade.
DHI-XVR-4108HS – 8 Channel Penta-brid HD Digital Video Recorder. DHI-XVR-4108HS Support HDCVI/CVBS/HDTVI/AHD video inputs. >Max 5/10/18 channels IP camera inputs,each channel up to 5MP (2MP for 4ch) >Max 20/40/72Mbps Incoming Bandwidth. >Long transmission distance over coax cable.
IPC-HFW4431R-Z and a IPC-HDW4431C-A. Yup classic time issue..Try this, leave the time zone alone its default is GMT+08:00..sync the cams to your PC make sure your time is set correct. Uncheck ALL DST and SYNC with stuff. It should look something like this. ------->.
Step by Step Instructions. 1. Set up tab → event → video detect. 2. Check enable → Choose which cameras you want motion detect set for. You may copy motion settings from one channel to another or from one channel to all by selecting the "Copy" button on the lower left.
Figure 5-243 Step 2 Configure the parameters. For details, see Table 5-74. Parameter Description Enable or disable the password reset function. It is enabled by default. Password Reset If the password reset function is disabled, you can find back the password by the security questions. Make sure you have configured the security questions.
Figure 2-31 Remove cover Step 3 Align the screws of the HDD with the holes on the DVR and fasten them. Page 31 User's Manual Figure 2-32 Install HDD Step 4 Use the HDD cable and power cable to connect HDD and mainboard. Page 32 User's Manual Figure 2-33 Connect cables Step 5 Put back the cover.
This unit auto detects SD or CVI on each channel and also accepts IP. It also supposedly allows longer UTP (CVI) runs with baluns than earlier models. We tested the unit with 8 SD analog cameras running with all set to the highest quality settings (D1, 960h, VBR and "6" - highest quality, max bit rate).

1) Remove the battery from the DVR. 2) Connect the screen to the DVR. 3) The password is generated based on the current set date in the DVR, when we pulled out the battery, it should be reset by the year 2000 based on this, we use the login admin and password 668648 or 000000 for logging in. Also you can use the following program that can

signal over coaxial cable. The devices produce video signal with megapixel resolution and require connected XVRs to achieve high-speed, long-distance, and zero-lag transmission of the signal. They are applicable to various scenes, such as roads, warehouses, underground parking lots, bars, pipelines, and gas stations. Application Application

Home. Réponses rapides. Comment à L’usine Réinitialiser DAHUA DVR ? La seule façon de réinitialiser est via le menu « Paramètres par défaut » – comme les réglages d’usine.

Step by Step Instructions. 1. Open ConfigTool. Select "Password Reset" on the left. Find the device in the list, and verify it has the XML reset option under "Support". Click the Reset button on the right. You can select Multiple cameras per export file. Please select all the IP Cameras then click on "Batch Reset" to make a single XML file.

Dahua. The camera should be connected to power. Click the reset button for at least 5 seconds until the camera restarts, and then the camera will be restored to factory default settings. If there is a PWR indicator, you can check the indicator go off and on again.
Important Note: This video is made for Educational and Informational Purpose Only.Important Note: This video is made for Educational and Informational Purpos
First, check to see if your DVR is set to the correct resolution. To do this, go into the DVR’s main menu and navigate to the ‘Display’ settings. If the resolution is set to anything other than ‘Auto’, change it to ‘Auto’ and save your changes. If that doesn’t fix the problem, try restarting your DVR.
Install SmartPSS in OSX M1 Chip. Install. Install SmartPSS on a Non-Administrator Account. Add Device. Add DVR/NVR to SmartPSS (IP) Add Device. Add DVR/NVR via Serial Number to SmartPSS (P2P) View Device. View Device in SmartPSS. The Dahua IPC-A35 can be found using zoneminder 1.32.x ONVIF "Monitor Probe" feature. At the Console screen, click on "Add" to add a new camera. Then on the top right, click on "ONVIF" and follow the configuration dialogue. In general, use the following configuration: Config Tab. Option.